Detection, warning and cause and effect, designed and installed to BS 5839.
A fire alarm system detects a fire early and warns everyone in the building in time to get out. Detectors watch for smoke or heat, the panel works out where the signal came from, and sounders and beacons tell people to leave. Call points by the exits let anyone raise the alarm by hand.
What the panel does next is the cause and effect: which sounders ring, which doors release, which vents open. It is mapped out for each building, not left as one generic response.
Addressable or conventional
Addressable systems report the exact device, so you know it is the detector outside flat 14, not just the third floor. Conventional systems report by zone. They cost less and suit smaller, simpler buildings. Wireless panels use radio-linked detectors where running new cable is impractical, such as listed buildings.
01 / 03
Detectors, sounders and call points, wired back to one panel that decides what happens next.
The equipment
Control panels
Addressable, conventional or wireless, sized to the building.
Optical smoke detectors
General coverage for most rooms and corridors.
Heat detectors
Kitchens and plant rooms, where steam or fumes would trip a smoke detector.
Multi-sensors
Smoke and heat in one head, fewer false alarms.
Aspirating detection
Sampling pipes for very early warning in server rooms and high-value storage.
Manual call points
Break-glass units by exits and on escape routes.
Sounders, beacons and VADs
Audible and visual warning, including for people who are deaf or hard of hearing.
Interfaces
AOV vents, door holders, mag locks, sprinklers and air handling plant, all released on the alarm signal.
Repeater panels
Alarm status at the entrance or security desk.
Remote signalling
Wired ready for an alarm receiving centre (ARC), and we can put you in touch with a monitoring provider.
BS 5839 and the categories
BS 5839-1 covers non-domestic buildings, including the communal areas of larger residential blocks. BS 5839-6 covers dwellings and HMOs. Part 1 sets a category by what the system protects and how much of the building it covers.
Category
Coverage
L1
Life safety, detection in virtually every room.
L2
Escape routes plus specific higher-risk areas.
L3 and L4
Escape routes, corridors and stairs.
L5
Bespoke, for a localised risk named in the fire risk assessment.
P1 and P2
Property protection, the whole building or specific high-risk rooms.
M
Manual call points only, no automatic detection.
Most buildings combine them, often L2 or L3 with P2 for high-value rooms. The fire risk assessment sets the category, so we survey before we quote.
02 / 03
Category, zones and device positions are set against BS 5839 before a cable goes in.
BAFE accredited
BAFE is the independent accreditation scheme for fire alarm contractors in the UK. An outside body audits our design, installation, commissioning and maintenance work on an ongoing basis, so your fire risk assessor, building control or insurer does not have to take our word for it.
Testing, servicing and the log book
Weekly
Test a different call point, done by a responsible person on site.
Every six months
Full service by a competent contractor: detectors, panel, wiring and batteries.
Every visit
Tests, faults and remedial work recorded in the log book kept on site.
Commissioning proves every device and every cause and effect, signed off by the team that installed it.
Blocks of flats since Grenfell
The Fire Safety Act 2021 brought external walls and flat entrance doors into scope, and the Building Safety Act 2022 added duties for higher-risk buildings. Many blocks are replacing a waking watch with a permanent common-parts alarm, which usually lets the waking watch stand down at a fraction of the ongoing cost.
What we do
We survey, specify, install, commission and maintain, all in-house, so one team stays accountable from design to every service visit. For an existing system with no clear history, we run a takeover survey and bring it up to BS 5839 before it moves onto a maintenance contract.
We work in offices, apartment blocks, HMOs, schools, industrial units and mixed-use buildings, and we commission fire alarms alongside AOV smoke ventilation and door entry and access control as one coordinated scheme.
Start with the building. The category follows from the risk assessment.
Every system is designed, installed and serviced by the same in-house team.
BS 5839StandardPart 1 for non-domestic, Part 6 for dwellings
WeeklyCall point testLogged by the responsible person
6 monthsFull serviceBy a competent, accredited contractor
Five quick questions, about a minute. We read every brief and aim to call you back within one working day, no obligation. Rather talk now? Call 01922 660923.
1 of 5System
FAQ
What responsible persons ask us.
How often does a fire alarm have to be tested and serviced?+
A manual call point should be tested weekly by someone on site, a check that takes a few minutes. A full service by a competent contractor is required at least every six months under BS 5839-1. We run the six-monthly service and can support the weekly test, with every visit logged.
What is the difference between an addressable and a conventional fire alarm?+
An addressable system identifies the exact device that triggered, down to the individual detector. A conventional system only identifies the zone. Addressable suits larger or more complex buildings; conventional is a cost-effective fit for smaller, simpler premises.
What category of fire alarm does my building need?+
It depends on the building's use, layout and occupancy, and is properly set by a fire risk assessment rather than guessed from a floor plan. Categories run from L1, the most complete life-safety coverage, through to L5, a bespoke localised category, plus P1 and P2 for property protection and M for manual-only systems. Our free phone consultation works through your building and explains which category fits.
Do I need to keep a log book for the fire alarm?+
Yes. BS 5839-1 requires every test, service and remedial action to be recorded and kept available for inspection. It is one of the first things a fire risk assessor, insurer or fire officer will ask to see, and a missing entry is treated the same as a missed test.
Why does our block need a common-parts fire alarm now when it didn't before?+
Standards and expectations for residential blocks have moved on since Grenfell, particularly through the Fire Safety Act 2021 and the Building Safety Act 2022. Many blocks that relied on a temporary waking watch are installing a permanent common-parts alarm system instead, which usually costs significantly less over time than continuing to pay for a waking watch.
Can you take over and service a fire alarm another company installed?+
Yes. We inspect the panel, detection and wiring against BS 5839 regardless of who installed it, log any defects, carry out remedial work to bring the system up to standard, and put it onto a planned maintenance contract from there.